ADE7754
Watt Mode Register (0Dh)
The phases involved in the active energy measurement of the ADE7754 are defined by writing to the WATMODE register. Table XIV
summarizes the functionality of each bit in the WATMODE register.
Table XIV. WATMODE Register
Bit
Bit
Default
Location
0-2
Mnemonic
LWATSEL
Value
7
Description
These bits are used to select each part of the formula separately, depending on the line active
energy measurement method. The behavior of these bits is the same as WATSEL bits. Bit 2
selects the first term of the formula and so on.
3-5
WATSEL
7
These bits are used to select each part of the formula separately, depending on the active
energy measurement method. These bits are also used to enable the negative power detection
available in Bits 12 to 14 of CFNUM register. See Table XI. Setting Bit 5 to Logic 1 selects
the first term of the formula (VA
IA or VA
(IA – IB)). Setting Bit 4 to Logic 1 selects the
second term of the formula (VB
IB or 0 depending on WATMOD configuration). Setting
Bit 3 to Logic 1 selects the last term of the formula (VC
IC or VC
(IC – IB)). Any combi-
nation of these bits can address calibration and operational needs.
6-7
WATM
0
These bits are used to select the formula used for active energy calculation.
WATM1
WAVM0
Active Energy Calculation
0
0
VA
IA + VB
IB + VC
IC
0
1
1
0
VA
VA
(IA – IB) + 0 + VC
(IA – IB) + 0 + VC
(IC – IB)
IC
1
1
Reserved.
VA Mode Register (0Eh)
The phases involved in the apparent energy measurement of the ADE7754 are defined by writing to the VAMODE register. Table XV
summarizes the functionality of each bit in the VAMODE register.
Table XV. VAMODE Register
Bit
Bit
Default
Location
0-2
Mnemonic
LVASEL
Value
7
Description
These bits are used to select each part of the formula separately, depending on the line appar-
ent energy measurement method. The behavior of these bits is the same as VASEL bits. Bit 2
selects the first term of the formula, and so on.
3-5
VASEL
7
These bits are used to select separately each part of the formula, depending on the apparent
energy measurement method. Setting Bit 5 to Logic 1 selects the first term of the formula
(VA rms
IA rms ). Setting Bit 4 to Logic 1 selects the second term of the formula (VB rms
IB rms
or (VA rms +VC rms )/2
IB rms or VA rms
IB rms depending on VAMOD configuration). Setting
Bit 3 to Logic 1 selects the first term of the formula (VC rms
bits can address calibration and operational needs.
IC rms ). Any combination of these
6-7
VAMOD
0
These bits are used to select the formula used for active energy calculation.
VAMOD1
VAMOD0
Apparent Energy Calculation
0
0
VA rms
IA rms + VB rms
IB rms + VC rms
IC rms
0
1
VA rms
IA rms + (VA rms + VC rms )/2
IB rms + VC rms
IC rms
1
0
VA rms
IA rms + VA rms
IB rms + VC rms
IC rms
1
1
Reserved.
–38 –
REV. 0
相关PDF资料
EVAL-ADE7755ZEB BOARD EVALUATION FOR AD7755
EVAL-ADE7758ZEB BOARD EVAL FOR AD7758
EVAL-ADE7759EBZ BOARD EVALUATION FOR ADE7759
EVAL-ADE7762EBZ BOARD EVALUATION FOR ADE7762
EVAL-ADE7763ZEB BOARD EVALUATION FOR ADE7763
EVAL-ADE7816EBZ BOARD EVALUATION FOR ADE7816
EVAL-ADE7878EBZ BOARD EVAL FOR ADE7878
EVAL-ADE7880EBZ BOARD EVAL FOR ADE7880
相关代理商/技术参数
EVAL-ADE7755EB 制造商:Analog Devices 功能描述:EVAL BOARD ENERGY METERINGW/PULSE OUTPUT - Bulk
EVAL-ADE7755EBZ 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with Pulse Output
EVAL-ADE7755EBZ1 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with Pulse Output
EVAL-ADE7755ZEB 功能描述:BOARD EVALUATION FOR AD7755 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:- 标准包装:1 系列:- 主要目的:电信,线路接口单元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要属性:T1/J1/E1 LIU 次要属性:- 已供物品:板,电源,线缆,CD 其它名称:82EBV2081
EVAL-ADE7756EB 制造商:Analog Devices 功能描述:EVAL BD DOCUMENTATION ADE7756 ENERGY METERING IC - Bulk 制造商:Rochester Electronics LLC 功能描述:
EVAL-ADE7757AEBZ 制造商:Analog Devices 功能描述:EVALUATION BOARDS - Bulk
EVAL-ADE7757EB 制造商:Analog Devices 功能描述:EVAL BOARD ENERGY METERINGW/PULSE OUTPUT - Bulk
EVAL-ADE7758ZEB 功能描述:BOARD EVAL FOR AD7758 RoHS:是 类别:编程器,开发系统 >> 评估演示板和套件 系列:* 标准包装:1 系列:PSoC® 主要目的:电源管理,热管理 嵌入式:- 已用 IC / 零件:- 主要属性:- 次要属性:- 已供物品:板,CD,电源